Q4: Other Problems - Yamaha PJP-EC200 User Manual

Conference echo canceller
Hide thumbs Also See for PJP-EC200:
Table of Contents

Advertisement

Q4: Other problems

Problem
Cannot synchronize the
clock with an NTP server.
An incorrect time is not
displayed.
The clock setting cannot be
saved.
The phantom power is not
supplied.
Cannot output your own
voices from your speakers.
The audio cannot be output.
Firmware update fails.
Cannot update the firmware
by TFTP.
54
Cause
The IP address or domain name of the NTP
sever is incorrect.
A route to connect with the specified NTP
server has not been set.
The time zone setting is incorrect.
The built-in battery (for clock memory) is
run out.
The phantom power setting is incorrect.
The internal mixer is disabled.
The mute function is turned on in the web
menu.
Timeout happens because the timeout
period for HTTP revision-up is too short.
The download URL setting is incorrect.
The DNS server setting is incorrect.
The access permission setting is incorrect.
Remedy
• Check that the settings match the NTP server
information.
• Ping the NTP server to confirm that it is functioning.
Check the Internet service provider settings or route
settings.
Set the time zone according to your area.
• Supply the power to this unit for about five hours to
change the built-in battery.
• Have this unit serviced.
Enable the phantom power with the DIP switch or web
menu (depending on the DIP switch setting). (pages 10
and 32)
Enable the internal mixer. (pages 10 and 31)
Turn off the mute function. (page 30)
Increase the timeout period in the web menu. (page 48)
Configure the download URL setting correctly.
Configure the address of the DNS server correctly.
Configure the access permission setting correctly.
(page 49)

Advertisement

Table of Contents
loading

Table of Contents