Removing and Replacing the Memory Carrier Assembly Cover

This section describes how to remove and replace the memory carrier cover.

Removing the Memory Carrier Assembly Cover

To remove the memory carrier assembly cover, follow these steps:
1.
Unlock the cover release lever. Turn the cam 90 degrees counterclockwise.
2.
Pull up on the cover release lever to disengage the top cover and memory carrier assembly
cover from the chassis
3.
Slide the memory carrier assembly cover toward the left side of the server to free it from the
center of the chassis. Lift the cover off the chassis
Figure 2 Removing and Replacing the Memory Carrier Assembly Cover

Replacing the Memory Carrier Assembly Cover

To replace the memory carrier assembly cover, follow these steps:
1.
Position the cover onto the opening above the memory carrier assembly.
2.
Slide the cover toward the right side of the server until it is flush with the center chassis wall;
push firmly.
3.
Slide the top cover forward until it is flush with the front of the chassis.
4.
Push the cover release lever down into the latched position
5.
Lock the cover release lever by turning the cam 90 degrees clockwise.

Installing a Hot-Swappable Power Supply

The server can have one or two hot-swappable power supplies. These power supplies are located
at the rear of the server. The supported configuration of the server requires a minimum of one
power supply. You can install or replace a hot-swappable power supply using the procedures in
this section when power is on or off.
CAUTION:
ESD safety precautions can result in damage to the server.
NOTE:
A hot-swappable device does not require interaction with the operating system before
the device is removed from or installed into the server.
The DC power to the server does not have to be off to install or replace a hot-swappable power
supply.
(Figure
1).
Observe all ESD safety precautions before attempting this procedure. Failure to follow
(Figure
2).
(Figure
1).
Installing Additional Components
13