Serial Communications; Rs-232 Connection And Port Configuration; Serial Command Syntax - Runco RS-1100 CineWide Owner's Operating Manual

Rs-1100 series 1080p digital light processing projectors
Hide thumbs Also See for RS-1100 CineWide:
Table of Contents

Advertisement

To interface the RS-1100 with a home theater automation/control system or a PC running
terminal emulation software:
1. Connect it to your control system or PC as shown in Figure 3-13.
2. Start a terminal session on your PC using a terminal-emulation program, such as
HyperTerminal.
3. Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1
stop bit and no flow control. Set the baud rate to match that of the projector (115200,
38400 or 9600).
4. Press <Enter>. You should see a command prompt (>) in the terminal window.
5. Type a command from among those listed in Table 6-1 and press <Enter>. For
example, to change the aspect ratio to Letterbox, type x063x <Enter>.
Serial commands to the RS-1100 take the following form:
• Commands are in ASCII format.
• Commands are not case-sensitive; X001X and x001x are equivalent.
• A carriage return MUST follow each command.
The RS-1100 will not accept serial commands for 20 seconds after
Note
it is turned on or off.
Table 6-1. Serial Commands
Code
x001x
Power On
x002x
Power Off
x003x
Menu
x004x
Enter
x005x
Exit
x006x
Up (arrow key)
x007x
Down (arrow key)
x008x
Left (arrow key)
x009x
Right (arrow key)
x011x
Show active source and aspect ratio information
x021x
Keypad 1
x022x
Keypad 2
Runco RS-1100 Series Owner's Operating Manual

Serial Communications

6
Function
69
6.1
RS-232 Connection
and Port Configuration
6.2
Serial Command
Syntax

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs-1100 ultraSdc-1Rs-1100/sdc-1