To access the light path diagnostics panel, slide the blue release button on the
operator information panel to the left. Pull forward on the operator information panel
until the hinge of the panel is free of the server chassis. Then pull down on the
operator information panel, so that you can view the light path diagnostics panel
information.
Notes:
1. Do not run the server for an extended period of time while the light path
2. Light path diagnostics LEDs remain lit only while the server is connected to
The following illustration shows the controls and LEDs on the light path diagnostics
panel.
v Remind button: This button places the system-error LED on the front panel into
v NMI button: Press this button to force a nonmaskable interrupt to the
v Checkpoint code display: This display provides a checkpoint code that
14
IBM System x3755 M3 Type 7164: Installation and User's Guide
diagnostics panel is pulled out of the server.
power.
OVER SPEC
LOG
LINK
PS
FAN
TEMP
MEM
CNFG
CPU
VRM
DASD
Light Path Diagnostics
Remind mode. In Remind mode, the system-error LED flashes once every 2
seconds until the problem is corrected, the server is restarted, or a new problem
occurs.
By placing the system-error LED indicator in Remind mode, you acknowledge
that you are aware of the last failure but will not take immediate action to correct
the problem. The remind function is controlled by the iBMC.
microprocessor, if you are directed to do so by IBM service.
indicates the point at which the system stopped during the boot block and POST.
A checkpoint code is either a byte or a word value that is produced by UEFI. The
display does not provide error codes or suggest components to be replaced.
REMIND
PCI
SP
NMI
RAID
BRD
Reset button
Remind
button
NMI button
Check point
code display