Star Trac 4500 Owner's Manual page 68

Hide thumbs Also See for 4500:
Table of Contents

Advertisement

Item
Lowest
Value
ELMAX
25
LSTERR
0
LSTELV
0
LSTPOT
0
LSTRES
0
Default
Highest
Value
Value
57
170
0
25
0
255
0
255
2
0
Meaning
Representation of voltage to
elevation motor to obtain
maximum elevation (incline).
Multiply ELMAX by 0.019608 to
get actual voltage.
120 volt treadmill = 57
230 volt treadmill = 80
Representation of the last error:
18=NO STO
19=KEYDN
20=NORPM
21=SPCHG
22=EL STL
23=ELRNG
24=ELLOST
25=ELNOZ
Target elevation (Incline) A-D
value at last error. Multiply
LSTELV by 0.019608 to get actual
voltage. Muliply LSTELV by-
0.082 and add 19.67 to get
approximate degrees.
Representation of voltage to
elevation motor at last error.
multiply LSTPOT by 0.019608 to
get actual voltage. Multiply
LSTPOT by -0.082 and add 19.67
to get approximate degrees.
1=Incline was returning to 0% at
start-up at last error. 2=Incline had
finished returning to 0% at last
error.
(Continued)