5.1.56 Panel PCB ASSY
(1) Disconnect the connector of the Panel PCB harness from the Panel unit.
(2) Remove the four cup B M3x10 Taptite screws, release the two Hooks and remove the ALFB
panel.
Taptite, cup B M3x10
(3) Disconnect the connector of the Backlight module harness and LCD cable from the Panel
PCB ASSY.
Taptite, cup B M3x10
Panel PCB harness
ALFB panel
2
Hook
Fig. 5-95
Backlight module harness
Panel PCB ASSY
Fig. 5-96
5-72
1
Panel unit
LCD cable
Hook