Electrical Adjustments; Picture Quality Adjustment; Preparation - Sony KP-FR43M31 Service Manual

Ax1 chassis
Table of Contents

Advertisement

KP-FR43M31/FR43M91
RM-GA001

5-1. PICTURE QUALITY ADJUSTMENT

5-1-1.

Preparation

1. Set in the service mode.
2. Set respective items as follows.
Adjustment Condition
DRC-MF : DRC1250
PICTURE QUALITY : CUSTOM
3D-NR MODE : OFF
ECO MODE : OFF
Category
PIC
LUMA
COLR
3. Connect the oscilloscope probe to the following point on
the UG board.
Input Signal
Video Color Bar (white & color 75%)
RF Color Bar (white & color 75%)
Measurement Point
UG Board CN1504:
pin R/G t VG
A5
pin B
B5
Note : After the adjustment 5-3. Picture Quality Adjustment,
these adjustment parameters must be recovered to
the original condition.

ELECTRICAL ADJUSTMENTS

Item
00
PIC
01
COL
05
PIOF
01
GAMM
06
BLK
00
CLOF
01
HUOF
02
RDRV
03
GDRV
04
BDRV
05
RCUT
06
GCUT
07
BCUT
09
DCOL
t VB
SECTION 5
Original Condition
DRC-MF : DRC1250
PICTURE QUALITY : CUSTOM
3D-NR MODE : OFF
ECO MODE : OFF
Category
PIC
LUMA
Data
COLR
100
50
0
0
0
MCP
3
3
MID2
31
31
31
31
31
31
0
– 74 –
Item
Data
00 PIC
60 (CUSTOM)
01 COL
50 (CUSTOM)
05 PIOF
5 (CUSTOM)
01 GAMM
6 (CUSTOM)
06 BLK
0 (CUSTOM)
00 CLOF
0
01 HUOF
3
03 GDRV
33
06 GCUT
31
09 DCOL
3
14 ABLT
5 (NORMAL/V-COMP)
0 other
2
BCOL
5 (TWIN)

Hide quick links: