5-1. Picture Quality Adjustment

5-1-1. Preparation

1. Set in the service mode.
2. Set respective items as follows.
Adjustment Condition
DRC-MF
PICTURE MODE
3D-NR MODE
ECO MODE
Category
PIC
00
01
05
LUMA
01
06
COLR
00
01
02
03
04
05
06
07
09
3. Connect the oscilloscope probe to the following point on the
UG board.
Measurement Point
UG Board CN1504 :
t VG
pin R/G
A5
t VB
pin B
B5
Note : After the adjustment 5-3. Picture Quality Adjustment,
these adjustment parameters must be recovered to the
original condition.
SECTION 5

ELECTRICAL ADJUSTMENTS

: DRC1250
: HI-FINE
: OFF
: OFF
Item
Data
PIC
100
COL
50
PIOF
0
GAMM
0
BLK
0
CLOF
3
HUOF
3
RDRV
31
GDRV
31
BDRV
31
RCUT
31
GCUT
31
BCUT
31
DCOL
0
Original Condition
DRC-MF
PICTURE MODE : HI-FINE
3D-NR MODE
ECO MODE
Category
Item
PIC
00
PIC
01
COL
LUMA
01
GAMM
06
BLK
COLR
00
CLOF
01
HUOF
03
GDRV
06
GCUT
09
DCOL
MCP
14
ABLT
– 75 –