Restoring Power to LampLinc

LampLinc stores all of its settings, such as Links to other INSTEON devices, On-Levels/Ramp Rates, etc.,
with non-volatile memory. Because settings are saved in this non-volatile memory, they will not be lost in
the event of a power failure.
In the event of a power loss LampLinc will automatically return the load to the brightness level it had
before power was interrupted.

Resetting LampLinc to its Factory Default Settings

The factory reset procedure can be used to clear the LampLinc memory of all INSTEON Links,
programmed On-Levels and Ramp Rates, X10 addresses, etc.
1) If you are using a Controller to control LampLinc, be sure to Unlink it from the Controller. See
Unlinking LampLinc from an INSTEON Controller.
2) If you are using LampLinc to control any Responders, Unlink them from LampLinc. See Unlinking an
INSTEON Responder from LampLinc.
3) Unplug LampLinc for about 10 seconds
4) While holding down the Set button, plug LampLinc back in, making sure not to let go of the Set button
LampLinc
beep and its Status LED
will
5) Continue to hold down the Set button for 3 seconds and then release
LampLinc
double-beep and the load
will
LampLinc Owner's Manual
turn on solid green
will
turn on
will
Page 13 of 19