Installation and Setup Guide
Entd
A022-4063
Rcvd
A022-4064
Zn ZT P RC In
L
10 03 1 10 RF: 1s
Note that an "s" indicates
that a transmitter's serial
number has been
enrolled.

Wireless Key Programming Templates

This procedure programs the wireless keys, but a key is not active for arming/disarming until it is
assigned to a user number (see System Operation section, assigning attributes command).
Enter this mode by pressing the D key while at the *58 Menu mode Summary Screen. The following
prompts appear.
TEMPLATE ?
1–6
1
L
01
02
03 04
T
23
22
21 23
PARTITION
1
ENTER START ZONE
00 = QUIT
36
INPUT S/N
L
AXXX-XXXX
5-6
If Serial or Loop Numbers do not match after activating the transmitter
[ ∗ ] to continue
If the serial/loop number combination transmitted does not match the serial and loop
number entered, a display similar to the one below will appear. If the loop number does
not match, it will also be displayed. If so, activate the transmitter's loop input or
button one or more times.
If a match is still not obtained (i.e., summary display does not appear), press the [#] key
twice and enter the correct loop input or, if correct, press [#] again and then enter the
correct serial number.
Summary Screen
If the serial number transmitted matches the serial number entered, the keypad will beep
3 times and a summary display will appear, showing the programmed information for that
zone.
Press [∗] to begin programming the next zone. See first "Summary Screen" prompt
paragraph on previous page.
To exit this mode, enter 00 at the Summary Screen prompt.
Template Number
1–3 = 5804 templates; 4–6 = 5804BD templates
• Enter Template number 1–6 (see chart on next page).
See the defaults provided for each template in the chart that follows these procedures.
• Select from templates. Press [∗] to display template (1 shown selected).
NOTE: If necessary, press [#] to back up and re-enter template number.
• Press [#] if you want to return to *58 Menu mode summary screen.
Template Display
• When [∗] is pressed, the selected template will be displayed.
Top line of display represents loop numbers; bottom line represents zone type assigned
for each loop.
• Press [∗] to accept template.
Partition
VISTA-20P. 1 = partition 1; 2 = partition 2; 3 = common partition
• Enter the partition in which the key is to be active, then press [∗] to continue.
Start Zone Number
• The system will search for the highest available consecutive 4-zone group (the four zones
in the case of the 5804 and 5804BD), and display the lowest zone number of the group.
If you want to start at a different zone, enter the zone desired, and press [✱]. If that zone
number is displayed, the system has the required number of consecutive zones available,
beginning with the zone you entered. If not, the system will again display a suggested
zone that can be used.
If the required number of consecutive zones is not available at all, the system will display
"00".
To quit this mode and return to *58 Menu mode, enter 00 at this prompt.
• Press [∗] to accept.
Serial Number
• Manually enter the serial number printed on the label for the wireless key or press and
release the button to transmit its serial number.
• Press [∗] to accept the serial number. The system will check for a duplicate.
• If necessary, press the [#] key to back up without saving, and re-enter the serial number.
• Use the [A] key to move forward within the screen, and the [B] key to move backward.