Installation and Setup Guide
Arming Mode
AWAY
STAY
NIGHT-STAY
INSTANT
MAXIMUM
Panic Keys
There are three Panic keys (A, B, and C) that, if programmed, can be used to manually initiate alarms and
send a report to the central station.
Each key can be programmed for 24-hour Silent, 24-hour Audible, Fire, or Personal Emergency responses.
The programmed Panic response is activated when the appropriate key is pressed for at least 2 seconds.
The Panic keys are identified by the system as follows:
Keys
[A] (∗ ∗ ∗ ∗ /1)
[B] (∗ ∗ ∗ ∗ /#)
[C] (3/#)
IMPORTANT: For a Silent panic function (if programmed) to be of practical value, you must program a
report code for the zone and the system must be connected to a central station.
Setting the Real-Time Clock
Set the time and date by doing the following:
1.
+[#] + [6] [3]
(Security Code)
2. Press [∗] when the time/date is displayed.
A cursor appears under the first digit of the hour.
To move cursor ahead, press [
• Enter the 2-digit hour setting.
• Enter the 2-digit minute setting.
• Press [1] for PM or [2] for AM.
• Enter the last two digits of the current year.
• Enter the 2-digit month setting.
• Enter the 2-digit day setting.
3. To exit, press [∗] when cursor is at the last digit, or wait 10 seconds.
6-6
SUMMARY OF ARMING MODES
Features for Each Arming Mode
Exit Delay
Entry Delay
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Displayed as Zone
95
99
96
∗
]. To go back, press [#].
Perimeter Armed
Interior Armed
Yes
Yes
Yes
only those zones
listed in Night-
Stay zone list
Yes
Yes
Yes
No
No
Yes
Alpha Display:
DISARMED
READY TO ARM
TIME/DATE
SAT
04:04PM 10/17/00
Current time display
TIME/DATE
SAT
04:04P2000/10/17
Time/date editing display