Installation and Setup Guide
Configurable Zone Type Charts
ENTRY 1
Response when system disarmed and zone is:
Intact EOL
Open
RF zone normal
RF zone N/A
0 = normal
0 = normal
1 = alarm
4 = alarm
2 = trouble
8 = trouble
3 = fault
12 = fault
see note 5
Entry 1 = EOL + Open
ENTRY 3
Response when armed STAY and zone is:
Intact EOL
Open
RF zone normal
RF zone N/A
0 = normal
0 = normal
1 = alarm
4 = alarm
2 = trouble
8 = trouble
3 = fault
12 = fault
see note 5
Entry 3 = EOL + Open
ENTRY 5
Response when armed AWAY and zone is:
Intact EOL
Open
RF zone normal
RF zone N/A
0 = normal
0 = normal
1 = alarm
4 = alarm
2 = trouble
8 = trouble
3 = fault
12 = fault
see note 5
Entry 5 = EOL + Open
ENTRY 7
Display Faults
Power Reset/
Verification
0 = show alarms
0 = no
when armed
4 = power reset
& disarmed
after fault
1 = don't show
(with code +
OFF)
alarms when
12 = verification
armed
(show
(see zone
alarms, trbles,
type 16)
faults when
disarmed)
3 = never show
any alarms,
trbles, faults
Entry 7 = fault display + power
reset/verification
ENTRY 9
Alarm Sounds
Use Bell
Timeout
0 = none
0 = no
1 = steady
4 = yes
keypad
2 = steady bell
see fields *32,
and keypad
*33
3 = pulsing bell
and keypad
Entry 9 = alarm sounds + bell timeout + fire zone
4-10
ENTRY 2
Auto
Restore
Shorted
RF zn off-normal
0 = normal
0 = no
1 = alarm
4 = yes
2 = trouble
3 = fault
see note 6
Entry 2 = Short + auto restore + vent zone
ENTRY 4
Byp. when
disarmed
Shorted
RF zn off-normal
0 = normal
0 = no
1 = alarm
4 = yes
2 = trouble
3 = fault
see note 6
Entry 4 = Short + byp. disarmed + byp. armed
ENTRY 6
Dial Delay
(see field *50)
Shorted
RF zn off-normal
0 = normal
0 = no
1 = alarm
4 = use delay
2 = trouble
3 = fault
see note 6
Entry 6 = Short + dial delay + fault delay
ENTRY 8
Use Entry
Use Exit
Delay 1/2
Delay
0 = no
0 = no
1 = delay 1
4 = use exit
2 = delay 2
delay
Entry 8 = entry delay 1/entry delay 2 + exit delay +
interior zone type
ENTRY 10
Respond as
Trouble
Fire Zone
Sounds
0 = no
0 = none
8 = yes
1 = periodic
beep
see zone type
2 = trouble
09; see note 4
beeps
Entry 10 = trouble sounds + chime
Vent Zone
0 = no
8 = yes
Zone Conditions Represented
Configurable Zone Type Notes
1. Do not use the "fault delay" option
Byp. when
with a configurable zone type if it
armed
is set for an entry or exit delay,
otherwise unpredictable results
0 = no
may occur.
8 = yes
2. To create an interior type zone,
select "respond as interior zone
type" (entry 8, interior type = yes),
and set zone response to "fault" in
entries 3-4 to ensure fault
displays; do not set as "normal,"
Fault Delay
"alarm," or "trouble."
(see field *87)
3. Do not set fire zones to respond as
0 = no
a "fault" (entries 1-6), otherwise
8 = use delay
faults will not display unless the
[∗] key is pressed.
see note 1
4. 4219/4229 modules must use
EOLRs or unpredictable results
may occur.
Respond as
5. RF Zones: The "open" options in
Interior Type
entries 1, 3, and 5 are not
0 = no
applicable for RF zones. Use the
8 = yes
"intact EOL" option for normal RF
zone conditions and "shorted" for
see note 2
off-normal RF zone conditions.
6. a. Zone-Doubling/Double-
b. For double-balanced zones, this
c. For zone-doubled zones, both
Chime when Chime
Mode On
0 = no
4 = yes
INTACT
OPEN
SHORTED
EOL
ZONE-003-V0
in Entries 1-6
Balanced: A short on either
zone of a zone-doubled pair or
on a double-balanced zone
causes a tamper condition.
entry must be "0".
zones of the doubled pair must
be assigned the same response
to a short.