Honeywell ADEMCO VISTA-15PSIA Installation And Setup Manual page 39

Ademco vista series
Hide thumbs Also See for ADEMCO VISTA-15PSIA:
Table of Contents

Advertisement

10 INPUT TYPE
2 = AW (Aux wired zone)
RF TRANS
3
3 = RF (supervised RF transmitter
4 = UR (unsupervised RF transmitter)
5 = Button type RF transmitter (unsupervised).
This prompt is skipped for zones 2-8, or 2-16 if zone-doubling was enabled at "Hardwire
Type" prompt.
All of the RF transmitters have one or more unique factory-assigned input (loop) ID codes.
Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require
four programming zones).
RF Transmitters can be enrolled as one of the following types:
10 INPUT S/N:
L
A 0 2 2 - 4 0 6 4
1
10 INPUT S/N
L
A 0 2 2 - 4 0 6 4
?
10 INPUT S/N
L
A 0 2 2 - 4 0 6 4
1
XMIT TO CONFIRM
PRESS
TO SKIP
Input Device type (In)
[ ∗ ] to continue
Type
Description
RF
Sends periodic check-in signals, as well as fault, restore, and low-
(Supervised RF)
battery signals. The trans. must stay within receiver's range.
UR
Sends all the signals that the "RF" type does, but the control does
(Unsupervised RF)
not supervise the check-in signals. The transmitter may therefore be
carried off-premises.
BR
Sends only fault signals. It will not send a low-battery signal until it
(Unsupervised
is activated. The transmitter may be carried off-premises.
Button RF)
NOTE:
• For the built-in hardwired zones, the Input Device type is automatically displayed as HW
and cannot be edited.
• To change the input type of a previously programmed wireless device (type RF, UR, BR)
to a wired zone (type AW), you must first delete transmitter's serial number (see To
Delete A Serial Number prompt on next page)
Serial number Entry and Loop Number Entry
[ ∗ ] to continue
Used only when enrolling wireless transmitters.
a. Transmit two open/close sequences. If using a button-type transmitter, press and
release the button twice, but wait about 4 seconds before pressing the button the second
time.
OR
b. Manually enter the 7-digit serial number printed on the label of the transmitter. Then
press the [✱] key – the cursor will move to the "L" position. You can edit the loop
number, if necessary. When the loop number is acceptable, press [✱].
c. Press key [C] to copy the serial number previously enrolled (used when programming a
transmitter with several input loops).
Loop Number Change
[ ∗ ] to continue
NOTE: If the [C] key is used to copy the previously enrolled serial number, the cursor will
move to the Loop column (L) with the previous serial number displayed, and display a
highlighted question mark for the loop number.
Enter the loop number and press [✱]. The system will now check for a duplicate serial/loop
number combination.
Enroll Summary
[ ∗ ] to continue
If the serial/loop number combination is not a duplicate in the system, a display showing
the serial number and loop number entry will appear.
Confirmation Option
[ ∗ ] to continue
This prompt will only appear if you answered "Yes" at the first prompt in this section.
The system will enter a confirmation mode so that the operation of the actual programmed
input can be confirmed.
Activate the loop input or button that corresponds to this zone.
Menu Mode Programming
5-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-15pAdemco vista-20psiaAdemco vista-20p

Table of Contents