Ricoh K-C3 Service Manual page 162

Machine code: (b245/b276/b277/b268/b269)
Hide thumbs Also See for K-C3:
Table of Contents

Advertisement

B245/B276/B277/B268/B269 Service Manual
machine initialization. Normally, the value is 10. Other values indicate that the
adjustment has ended unsuccessfully.
White Target
4901 5*
Displays the target value for the white-level adjustment.
White Result
4901 6
Displays the result of the white-level adjustment.
White Display-Error
4901 8 Displays the return code of the white-level adjustment. When an error is
detected, SC143 is generated.
White Display-Overflow
4901 9 Displays a return code of the white-level adjustment. The code "1" (error) is
returned if the adjustment result is not in the range of the values in SP 4901 6.
White Number of Attempt
Displays how many times the white-level adjustment is retried. The value does
not include the first execution of the white adjustment. For example, if the value
is "2", this indicates that the white-level adjustment has been executed three
4901 10
times. The white-level adjustment can be executed 20 times or less. Therefore, if
the value is "20," this indicates that the white-level adjustment has ended
abnormally (as described, the value "20" does not include the first execution). If
the white-level adjustment is unsuccessful, the machine uses the result of the
latest, successful white-level adjustment.
Auto Adjustment Setting
4901 11 Displays the parameter of the white-level adjustment. The value is based on the
result of SP 4901 12.
Auto Adjustment-Result
Displays the result of the white-level adjustment. Normally, the value is between
4901 12
228 and 281 (including the both values). When the value is normal, it is stored as
the value of SP 4901 11.
Auto Adjustment-Error
Displays a return code of the white-level adjustment. The code "1" (error) is
4901 14
returned if the adjustment result value is less than 228 or larger than 281 (
SP4901 12).
Exposure Lamp ON
4902*
4902 1 Turns the exposure lamp on or off. To turn off the exposure lamp, select "OFF".
[0 511 / 511 / 1/step]
[0 511 / 0 / 1/step]
[0 = Normal / 1 = Error]
[0 = Normal / 1 = Error]
[0 20 / 0 / 1/step]
[222 281 / 256 / 1/step]
[0 600 / 0 / 1/step]
[0 = Normal / 1 = Error]
18-Jan-06
153