Connection Using Only One Dcs-Lan - Shure CU 6110 User Manual

Central unit
Hide thumbs Also See for CU 6110:
Table of Contents

Advertisement

Danish Interpretation Systems
5.3
Max. number of units to be connected
The following tables shows the maximum
number of units, which can be connected to a CU
6110 Central Unit.
In the tables the 'Feeding Cable' is defined as the
cable between the CU 6110 and the first
Conference Unit and the 'Interconnecting Cable
5.3.1
Connection using only one DCS-LAN chain
The following tables show the maximum number
of units, which can be connected to one DCS-LAN
chain output when only one DCS-LAN chain is in
use.
5.3.1.1
DC 6120 P, DC 6190 P, DM 6680 P
Conference Units
Length of
Length of inter
Feeding Cable
connecting
Cable
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 5.3-A
5.3.1.2
DC 6990 P Conference Unit
Length of
Length of inter
Feeding Cable
connecting
Cable
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 5.3-B
Total cable
Max. number
length
of units
51 m
42
67 m
38
83 m
34
122 m
23
165 m
16
88 m
40
98 m
35
108 m
30
140 m
21
178 m
15
Total cable
Max. number
length
of DC 6990 P
35 m
22
53 m
22
70 m
21
112 m
13
158 m
9
56 m
25
72 m
22
90 m
19
124 m
13
166 m
9
User Manual CU 6110 rev C.docx
is defined as the cable connecting two
conference
units.
interconnection cables must be minimum
AWG24 if the number of units in the tables is to
be used.
5.3.1.3
CM/DM 6080 F / DM 6620 F
Chairman/Delegate
Length of
Length of inter
Feeding Cable
connecting
Cable
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 5.3-C
5.3.1.4
CM/DM 6680 F Chairman/Delegate
Units connected
Length of
Length of inter
Feeding Cable
connecting
Cable
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 5.3-D
5.3.1.5
MU 6040 C/D and MU 6042 D
Length of
Cable length
Feeding Cable,
between each
MU 6040
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
100 m
1 m
150 m
1 m
Figure 5.3-E
With no Audio in the loudspeaker
User Manual
Feeding
cables
Total cable
Max. number
length
of DC 61xxP
39 m
30
56 m
27
73 m
24
115 m
16
160 m
11
64 m
28
78 m
25
94 m
23
130 m
16
170 m
11
Total cable
Max. number
length
of DC 61xxP
35 m
27
53 m
24
70 m
21
113 m
14
159 m
10
58 m
25
72 m
22
88 m
20
126 m
14
166 m
9
Total cable
Max. number
length
of MU 6040
168 m
80
178 m
75
188 m
70
200 m
51
200 m
26
151 m
52
191 m
42
and
13

Advertisement

Table of Contents
loading