Shure CU 6110 User Manual page 39

Central unit
Hide thumbs Also See for CU 6110:
Table of Contents

Advertisement

DIS Digital Conference System
#
Menu
21.
22.
Figure 6.5-B
CU 6110 Browser Setup
Settings
User Manual CU 6110 rev C.docx
User Manual
Description
Voice Activation –
Those
settings
determines
behavior of the system when
working in VOX mode
The 'Voice detection threshold' can
be set to values ranging from '-12
to '8' in steps of '1'.
The default value is '0'. Setting to a
lower value makes the microphone
more sensitive.
The 'Voice detection release time'
can be set to values from 1 to 10
seconds in 0.5 sec step.
This setting is used for setting the
time from the delegate stops talking
until the microphone turns off. The
default value is 4 sec.
When "Book Drop" Feature is
enabled a short 'unwanted' noise
will only make the microphone to
open a few seconds.
"Last Mic Stays Open" feature is
used when the DCS 6000 system is
used for video or audio conferences
where
equipment
with
canceling feature is in use.
Auto Off –
When 'Microphone Auto Off' is set
to 'On' a Conference unit will
automatic turn off the microphone
when the delegate stops talking.
The time is determined by the 'Auto
Off time' setting.
The 'Automatic Off Time' sets the
time
from the
delegate
speaking
until the
microphone
turns off. The value can be set from
5 to 60 seconds in 5 second steps.
The default value is 5 sec.
When the system is set to VOX
mode Auto Off settings are disabled.
Report –
If a report is needed for factory
diagnostic purposes.
The report can be printed using an
installed printer on the PC or saved
to a html file.
the
echo-
stops
39