Flow Sensor Specifications; Electronic Unit Box - Omega FMG600 Series User Manual

Electromagnetic flow meters
Table of Contents

Advertisement

4.1.8. Flow sensor specifications

Sensor size
Operational pressure
Mechanical connection
grounding
Limit flow velocities of measured liquid
Maximum temperature of measured liquid
Minimum conductivity of measured liquid
Empty pipe alarm
Lining
Measuring electrodes
Protection class
Storage temperature

4.2. Electronic unit box

The signal-processing electronic unit is accommodated in a cast aluminum box coated on the surface with
paint of hue RAL 1017. The box is held by four M5 bolts with hexagonal socket heads. Upon loosening the
bolts slightly the box can be rotated around horizontal axis through ±180°. At the rear of the box is a terminal
board under a lid held in position by six bolts with hexagonal socket heads. At the rear bottom part of the box
there are cable glands and a special valve preventing condensation of the air humidity inside the box. The
unused gland openings shall be blinded. The front panel of the box is fitted with a two-line background-
illuminated display unit and a four-button membrane keyboard.
Prior to putting the meter in service, check the correct sealing of all active glands, blinding of the unused
ones and tightening of the bolts holding the terminal board lid.
Design, Assembly and Service Manual
Induction flow meter FMG600 series
Flanged sensors, ½ " to 12 " (DN 15 to DN 300)
Tri Clover, ½ " to 2 ½ "
PN 10 (1.0 MPa) for DN 15 to 300, Tri Clover
Flanges acc. to 150# ANSI B
Tri Clover
On flanges
Grounding rings
grounding electrode
From 0.33 to 32.81 ft/s (0.1 m/s to 10 m/s)
up to 302 ºF (150 ºC)
20 μS/cm
Optional from 2 " (DN 50) -EPT
Teflon (PTFE)
Hastelloy C4 standard
Platinum/gold -GGE
Tantalum –TGE
IP 67
14 to 158 ºF (-10 ºC to +70 ºC) at max. relative air
humidity 70%