Omega FMG600 Series User Manual page 23

Electromagnetic flow meters
Table of Contents

Advertisement

4. Total difference
The difference between fluid volumes passed in the positive (+) and negative (-) directions since the
measurement start, or temporary difference from the last resetting of the temporary difference data.
Total difference
1111.111 m3
Display reading: Total difference
5. Operational time
The length of the time period, in hours and minutes, counted from the first meter start, or the length of the
temporary time period measured since the last resetting of the temporary time data.
Operational time
12345:55 h:m
Display reading: Operational time
Upon switching off the induction flow meter, the data readings under items 3, 4, 5 and 6 are stored at the
EEPROM unit and restored upon each new meter start.
6. Percentage flow rate
Flow rate information in the form of a horizontal bar whose length corresponds to the flow rate value in per
cent of a selected 100% value (need not necessarily be the same as the maximum flow rate for the given
sensor). The figure on the right side offers the digital form of the same information. The minus sign before
the figure indicates negative flow data.
Percent.flowrate
▌▌_____ - 20%
Display reading: Per cent flow rate
7. Last error
Abbreviated text of the last error message.
Last error
7:sensor discon.
Display reading: Last error
In the case of a meter error, the display will immediately show a message including a short description of the
error concerned. Upon depressing push-button
abbreviated error message and error code are stored in the "previous errors" register. While an error is
indicated, the measurement functions continue undisturbed. In the cases of errors E6 and E7, zero flow rate
is indicated throughout the error condition duration.
The user may review earlier error codes and messages up to 255 previous error messages stored in the
error register. To access this function, depress push-button
E-XXX YYY/ZZZ are: XXX the error code, YYY error ordinal number, and ZZZ the total number of error
codes stored in the register. To page in the list use push-button
depress push-button
Design, Assembly and Service Manual
Induction flow meter FMG600 series
. Error register is reset with switching power on.
Temp.difference
700.111 m3
Temporary time
543:21 h:m
Last error
E-007 015/015
, the meter will return to the data display mode, while the
(previous error display). In the data format
Page 21 of 44