  • Page 1 User's Guide Shop online at omega.com email: Info@omega.com For latest product manuals: omegamanual.Info FPR300 FPR310 FPR300/310 SERIES Low-Flow Meter...
  • Page 2 Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
  • Page 3: General Information

    GENERAL INFORMATION These versatile impeller flowmeters are available in 3/8", different types of controls, including a full range of Omega rate 1/2”, 3/4”, and 1" nominal pipe sizes with female NPT displays and controls. The Omega DPF75-A provides flow rate threads (SAE optional).
  • Page 4: Installation And Connections

    Signal it is necessary to order the FPR flow sensor with some form Black Black of 4-20 mA transmitter. One option is the Omega DPF75- Ground Ground A, which provides rate and total readings as well as 4-20 mA output.
  • Page 5: Maintenance And Repair

    MAINTENANCE and REPAIR Sensor Replacement. The sensor ordinarily does not need Rotor Replacement. There is only one moving part to this replacement unless it is electrically damaged. If replace- meter. The bearings are made of ruby, which rarely wears ment is necessary, unthread the sensor by hand. Thread out or needs replacement unless they have been physically the replacement sensor in and tighten by hand.
  • Page 6: Parts List

    PARTS LIST FPR Parts Listing FPR300 FPR310 Body Flow Direction Label 19036 19036 Bearing Assembly (2 required) 16772 16772 Bearing Removal Tool (not shown) 26108 26108 Rotor with Shaft Kynar/ceramic (2 magnet) 11127 11127 Kynar/carbide (2 magnet) 11129 11129 Kynar/ceramic (6 magnet, high res) 11132 11132 Kynar/cabide (6 magnet, high res)
  • Page 7 Should any Product(s) be used in or with any nuclear installation or a c t i v i t y, medical application, used on humans, or misused in any way, OMEGA assumes no re s p o n s i b i l i t y...
  • Page 8: M O N I Toring And Contro L

    W h e re Do I Find Eve rything I Need for P rocess Measurement and Control? OME GA…Of Cours e ! Shop online at omega.com T E M P E R AT U R E Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD &...