FMG90B Series Table of contents page About this operating manual ..................4 Device description ..................... 5 1.1 Delivery, unpacking and accessories ..............5 1.2 Intended use......................6 1.3 Exclusion of liability ....................6 Safety instructions ..................... 7 Construction and function ..................8 Installation of FMG90B ....................
If you have any problems or questions, please contact your supplier or contact us directly omega.com Tel: (203) 359-1660 e-mail: info@omega.com Hazard signs and other symbols used: WARNING! / CAUTION! Risk of injury! This sign indicates dangers that cause personal injuries that can lead to health defects or cause considerable damage to property.
FMG90B Series Device description Device description The FMG90B series from Omega is a flow sensor without moving parts. The measurement is performed using magnetic induction. The FMG90B is used for measuring or metering water and electrically conductive fluids. The compact design and independence from the intake and discharge sections allows the FMG90B to be used under a variety of conditions.
20 μS/cm. WARNING! No safety component! The magnetic inductive flow sensor of the FMG90B series is no safety component in accordance with Directive 2006/42/EC (Machine Directive). Never use the FMG90B as a safety component.
In order to guarantee that the device operates safely, the operator must act competently and be conscious of safety issues. OMEGA provides support for the use of its products either personally or via relevant literature. The customer verifies that our product is fit for purpose based on our technical information.
Construction and function FMG90B Series Construction and function Components: Housing: The Housing consists of plastic and has the IP65 degree of protection. Electrical connection: The electrical connection is made via 4-pin plug M12x1. Operation / flow indicator LED.
FMG90B Series Installation of FMG90B Installation of FMG90B Before installing, check that the wetted materials of the device are suitable for the media being used ( § 9 “Technical data”). the equipment is switched off and is in a safe and de-energized state.
Installation of FMG90B FMG90B Series Installation can occur in horizontal and vertical pipes. The flow sensor is only suitable for • application in completely filled pipe systems. As a matter of principle magnetic inductive flow sensors are widely independent from the •...
Connection cable: Suitable connection cables with molded coupling socket M12x1 are available in different lengths as OMEGA accessories. The maximum permissible cable length is 10 m. Connection 4-pin plug M12x1: Screw the coupling socket of the connection cable to the plug of the FMG90B.
Electrical connection FMG90B Series 5.1 Wirings Pinout: The pinout differs according to the chosen configuration of the device. Pinout: Possible pinout: Pin 1: Pin 2: n. c. (not connected) / Analog U/I Pin 3: Pin 4: Frequency M12x1 Connect the connection cable according to your version and the pinout on the type plate.
FMG90B Series Commissioning and measuring operation Commissioning and measuring operation Before switching on the FMG90B for the first time, please follow the instructions in the following section. 6.1 Commissioning Check that the FMG90B has been installed correctly and that all screw connections are sealed.
Maintenance and cleaning FMG90B Series Maintenance and cleaning Maintenance: The FMG90B is maintenance-free and cannot be repaired by the user. In case of a defect, the device must be replaced or sent back the manufacturer for repair. CAUTION! Material damage! When opening the device, critical parts or components can be damage.
FMG90B Series Disassembly and disposal Disassembly and disposal CAUTION! Risk of injury! Never remove the device from a plant in operation. Make sure that the plant is shut down professionally. Before disassembly: Prior to disassembly, ensure that the equipment is switched off and is in a safe and de-energized state.
Technical data FMG90B Series Technical data The technical data of customized versions may differ from the data in these instructions. Please observe the information specified on the type plate. 9.1 Characteristics FMG90B Type FMG93B FMG96B FMG98B FMG915B FMG920B FMG925B Measurement device characteristics Flow range [gpm] 0.026…0.53 0.066…1.3 0.26…5.3 0.66…13.2...
FMG90B Series Technical data 9.2 Materials table Component Material Component- wetted Housing Measuring tube POM or PVDF (option) Process connections POM or PVDF (option) O-ring EPDM or FKM (option) Electrodes and grounding Stainless steel 1.4404 or Hastelloy C®* rings * Available for FMG93B, FMG96B, FMG98B...