Assign Custom Flows - Pentair INTELLITOUCH User Manual

Control system for pool and spa
Hide thumbs Also See for INTELLITOUCH:
Table of Contents

Advertisement

IntelliFlo VF 3050 pump setup

Assign custom flows

From the Assign Custom Flows screen you can assign different (normally higher) flows to circuits/
features. For example you can set your SPA to run at 80 GPM. This way when you switch to spa mode,
the pump goes from the calculated fitter rate of about 28 GPM to 80 GPM while you use the spa. You
have a waterfall, and require 60 GPM when it's switched on.
To assign a specific flow to a circuit/feature:
1. From the main pump screen, press the left side button next to the select IntelliFlo pump.
2. On the next screen, press the left side button next to ASSIGN CUSTOM FLOWS.
3. First assign a circuit name. Press the left side button for the selected circuit. Use the PREV and
NEXT button to set the circuit. Then press the right side button to set the flow rate in GPM. The
selected circuit/feature must also be assigned a circuit function/feature. For details about assigning
a circuit function and feature circuit, see page 39 and 79.
4. When finished, press the lower SAVE button to save the setting. The previous pump parameters
screen is displayed. To modify another parameter select a feature from the parameter list. To exit,
press the EXIT button to return to the Equipment screen.
Press this
button go to four
additional circuits/
GPM settings
(Continued)
AUX 7
NONE
NONE
NONE
NEXT PAGE
MENU/SETP/EQUIP/INTELLIFLO/ASSIGN
BACK
SAVE
Save button
130 GPM
0 GPM
0 GPM
0 GPM
PREV
EXIT
Prev and Next buttons
(use to adjust pump
speed)
Press this button
to set the flow
rate (GPM)
IntelliTouch
Control System User's Guide
®
63