Secondary Timing Menu

The Secondary Timing menu (see
Total Access 3000 shelf in the event the primary clock is lost or degraded.
Shelf: 1 Slot: B
The Secondary Timing menu options are shown in
Option
Description
1
Bank Timing
N/A
Linecard
61181041L3-5A
Figure
26) is used to set an alternative clock source for the
Total Access System
Secondary Timing
1.
Bank Timing
Linecard
Selection:
'?' - System Help Screen

Figure 26. Secondary Timing Menu

Table 25. Secondary Timing Menu Options

Function
This option is used to set Bank Timing to one of the
following values:
• NONE
• LOCAL
• LOOP
• PLCP
• EXT BITS B
• EXT BITS C
• LINECARD (a value from 1 to 28, which corresponds to
the slots on the Total Access 3000 chassis).
This displays the Linecard setting, which is a value from 1 to
28 if the Bank Timing is set to Linecard, or n/a (not
applicable) if Bank Timing is set to another option.
MM/DD/YY HH:MM
ONLINE
: NONE
: n/a