Life Fitness Model 9500 Series HR and Telemetry Equipped Treadmills
How To... REMOVE AND REPLACE THE POWER MODULE
Tools Required: Standard screwdriver, 5/16" wrench, scribe, socket and ratchet set
WARNING: FAILURE TO OBSERVE SAFE PROCEDURES WHEN SERVICING THIS UNIT
Step 1
Turn the power OFF at the ON/OFF switch and then unplug the unit from the electrical outlet.
Step 2
With the help of another person, slowly tilt the unit on its right side.
Step 3
Ground yourself to the machine with a disposable anti-static strap.
Step 4
Using a hex key wrench, remove the three SCREWS from each of the RIGHT and LEFT
FRONT END CAPS. Remove the FRONT BELT GUARD.
Step 5
Remove the four SCREWS securing the REAR ROLLER GUARD to the FRAME. Remove the
GUARD and set it aside.
Step 6
At the location where the FRONT FRAME CAP was removed is the BELT TENSIONING BOLT.
The BOLT threads into a NYLON BLOCK which you can see through the slot in the FRAME
above it. Measure and note the distance from the NYLON BLOCK to the end of the slot or mark
the decal (if present) to locate the current position of the NYLON BLOCK where it meets the
threaded portion of the TENSIONING BOLT.
24
COULD RESULT IN INJURY FROM ELECTRICAL SHOCK.
(Continued)