6. Remove all CPUMEMRs, see
I
Before removing the CPUMEMRs, take a note on the installation
slot number for each CPUMEMR. Make sure that you reinstall the
CPUMEMR in the slot it was located before the replacement.
7. Remove all expansion cards and dummy modules in PCIe slots #8 to
#17, see
"Expansion cards and BBU" on page 105
I
Before removing the expansion cards, take a note on the
installation slot number for each card. Make sure that you reinstall
the card in the slot it was located before the replacement.
8. Remove the PCI Riser, see
15.1.3 Removing the fan cage
Figure 188: Removing the fan cage
Ê Loosen the captive screws (1).
Ê Lift the fan cage out of the chassis (2).
RX900 S2
"Removing the CPUMEMR" on page 190
"Expansion cards and BBU" on page 105
Upgrade and Maintenance Manual
Cables
295