Replacing The Heat Sink - Fujitsu PRIMERGY TX200 S2 Options Manual

Server system
Hide thumbs Also See for PRIMERGY TX200 S2:
Table of Contents

Advertisement

Processors
Ê Reinstall the processor fan holder (see
Ê Reinstall the ventilation duct over the system fans (see
Ê Reinstall the ventilation duct over the main memory (see
Ê Close the server, connect it to the power outlet, and switch it on as described
in the
chapter "Completion" on page
6.3

Replacing the heat sink

Ê Open the server as described in the
Ê Remove the ventilation duct over the main memory (see
Ê Remove the ventilation duct over the system fans (see
Ê Remove the heat sink (see
Ê Remove the processor fan holder (see
Ê Loosen the four screws on the heat sink socket in a crossover pattern (see
page
41).
Ê Loosen the heat sink by turning it back and forth and then lift it out.
Ê Clean the upper side of the processor using a lint-free cloth.
Ê Remove the protective cover from the new heat sink (see
Ê Place the heat sink on the processor socket (see
Ê Fasten the heat sink by tightening the four screws in a crossover pattern.
Ê Reinstall the processor fan holder (see
Ê Reinstall the ventilation duct over the system fans (see
Ê Reinstall the ventilation duct over the main memory (see
Ê Close the server, connect it to the power outlet, and switch it on as described
in the
chapter "Completion" on page
U41593-J-Z156-2-76
page
97ff.
chapter "Preparation" on page
page
33).
page
35).
page
97ff.
Options Guide
Replacing the heat sink
38).
page
39).
page
page
28).
page
32).
page
page
37).
38).
page
39).
page
30).
19ff.
36).
30).
43