Crestron Adagio AES Operation Manual page 25

Aes entertainment system
Hide thumbs Also See for Adagio AES:
Table of Contents

Advertisement

Crestron Adagio™ AES
AES Control Devices
AES with Control Devices
APAD
Fuse Replacement
Operations Guide – DOC. 6456B
Any combination of six AES control devices such as the APAD or the C2N-DBF12
can be simultaneously connected to the powered NET ports located on the upper-left
side of the rear panel. Refer to the following diagram and "Network Wiring" on page
17 for wiring information when connecting either APAD devices or C2N-DBF12
keypads.
C2N-DBF12
C2N-DBF12
If the AES does not power up when it is plugged into an AC outlet, the fuse may
need to be replaced. The fuse holder is located on bottom-right of the rear panel
(next to the power cord connector). To replace the fuse:
Press STANDBY to place the unit in Standby.
Disconnect power to the AES.
Use a flat-head screwdriver to push in the fuse holder.
While pushing in the fuse holder, turn screwdriver counterclockwise until
the fuse holder pops out.
Remove the fuse from the fuse holder and insert a new fuse.
CAUTION: Only use the specified type of fuse when replacing a blown
fuse. Failure to do so may cause damage to the AES.