Crestron Adagio™ AES
AES Control Devices
AES with Control Devices
APAD
Fuse Replacement
Operations Guide – DOC. 6456B
Any combination of six AES control devices such as the APAD or the C2N-DBF12
can be simultaneously connected to the powered NET ports located on the upper-left
side of the rear panel. Refer to the following diagram and "Network Wiring" on page
17 for wiring information when connecting either APAD devices or C2N-DBF12
keypads.
C2N-DBF12
C2N-DBF12
If the AES does not power up when it is plugged into an AC outlet, the fuse may
need to be replaced. The fuse holder is located on bottom-right of the rear panel
(next to the power cord connector). To replace the fuse:
•
Press STANDBY to place the unit in Standby.
•
Disconnect power to the AES.
•
Use a flat-head screwdriver to push in the fuse holder.
•
While pushing in the fuse holder, turn screwdriver counterclockwise until
the fuse holder pops out.
•
Remove the fuse from the fuse holder and insert a new fuse.
CAUTION: Only use the specified type of fuse when replacing a blown
fuse. Failure to do so may cause damage to the AES.