Chapter 5 — Troubleshooting and Maintaining the CV30
90
To preserve application programs through a clean boot, you
must store them in the Flash File Store.
To clean boot the CV30
1 Press the Power button to turn off the CV30 and hold.
2 Using a small pointed device (such as the end of the stylus) or
your finger, press the Reset switch on the top of the CV30.
Do not use force or a sharp object when pressing the reset
switch. You may damage the reset switch.
The blue light on the CV30 blinks once and the CV30 starts
the booting sequence.
3 Release the Power button when a Warning message appears
on the display asking if you want to clean boot the system.
4 Press the Volume Up button to start the clean boot process.
After some programs load, you are prompted to calibrate the
screen.
5 Calibrate the screen and then tap anywhere on the screen to
exit the application. The CV30 continues with the boot
process.
6 Reload any custom applications that may have been erased
during the clean boot and reset the time and date.