Troubleshooting - Windster RA35U30SS User Manual

Under cabinet/wall mount series
Hide thumbs Also See for RA35U30SS:
Table of Contents

Advertisement

14

TROUBLESHOOTING

WARNING!!!
Check to make sure all power sources are disconnected
before starting any troubleshooting. Safety gloves and glasses
should be worn when working on the unit. Serious injury or death
may occur if safety precautions are not followed.
Light Issue (All not
turning on)
Halogen/LED light issue
Light Issue (One light
not turning on)
Speed indicator not
showing speed levels
Burnt/melted control
switch
Speed levels not
working correctly
Unit lacking smoke
intake
Unit showing no power
indication
Unit making humming
noise
TROUBLESHOOTING
RA35 Series
1. Halogen lights may need to be changed.
2. New Transformerreplacement is required.
1. Replace burnt 20w light bulb.
2. LED may require new fixture or driver.
1. LED light may be defected.
1. Complete Control switch replacement is required.
1. Complete Control switch replacement is required.
1. Check all wiring to and from the unit.
2. Complete control switch replacement is required.
1. Check ducting for foreign object.
2. Ensure the ducting is properly sealed.
3. Clean filters to increase airflow.
1. Make sure the power source is working properly.
2. All wiring is connected.
1. Replace defective capacitor with new one.