Timing Rule; Timing Value; Table 1.15 Scsi Bus Control Timing Values - Fujitsu MAW3073 SERIES Specifications

Scsi physical interface 3-1/2" intelligent disk drives
Hide thumbs Also See for MAW3073 SERIES:
Table of Contents

Advertisement

1.5

Timing Rule

1.5.1

Timing value

Table 1.15, 16, 17 give the timing required for operations on the SCSI bus.
Timing description
1
Arbitration delay
2
Bus clear delay
3
Bus free delay
4
Bus set delay
5
Bus settle delay
6
Cable skew (1)
7
Data release delay
8
DIFFSENS voltage filter time
9
Physical disconnection delay
10
Power on to selection (2)
11
QAS arbitration delay
12
QAS assertion delay
13
QAS release delay
14
QAS non-DATA phase REQ(ACK)
peiod
15
Reset delay
16
Reset hold time
Note:
(1) Cable Skew is measured at each device connection with the transmitted skew subtracted from
the received skew. (2) This is a recommended time. It is not mandatory.
1-28
Table 1.15
SCSI bus control timing values
Type
Timing values
Min
2.4 µs
Max
800 ns
Min
800 ns
Max
1.6 µs
Min
400 ns
Max
4 ns
Max
400 ns
Min
100 ms
Min
200 µs
Max
10 s
Min
1000 ns
Max
200 ns
Max
200 ns
Min
50 ns
Min
200 ns
Min
25 µs
C141-C011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents