9.41 Low-voltage Power Supply PCB ASSY/Inlet Harness ASSY

(1) Disconnect the Harness from Hooks.
(2) Remove the four Taptite pan (washer) B M4x12DA screws, one Screw pan (S/P washer)
M4x8 screw, and the Low-voltage power supply ground plate, and then remove the
Low-voltage power supply plate from the Low-voltage power supply cover.
Taptite pan (washer) B
M4x12DA
Low-voltage power
supply plate
Low-voltage power
supply cover
(3) Disconnect the Connector (CN1) to remove the Inlet harness ASSY from the Low-voltage
power supply PCB ASSY.
Inlet harness ASSY
Low-voltage power supply PCB ASSY
Low-voltage power supply ground plate
Fig. 3-123
Connector
Fig. 3-124
3-97
Screw pan (S/P washer) M4x8
Taptite pan (washer) B
M4x12DA
Harness
CN1
Harness
Hook