Installing wall mount dispensers

• Wall mount dispensers are intended to be mounted above a
sink, eliminating the need for a drain pan.
• Before beginning installation verify that the sink size and
location meet the requirements shown in Fig. 7.
• If requirements are not met, a drain pan must be used to
prevent ice and water from falling on counter or fl oor.
• FAILURE TO TAKE THESE PRECAUTIONS COULD RESULT IN
SLIPS AND FALLS ON WET FLOORS
Fig. 7
Minimum sink requirements (without drain pan)
Front View
Front View
Sink centered
Sink centered
below dispenser
below chutes
21.5"
(54.7 cm)
(54.7 cm)
14.25"
(36.2 cm) min.
(58.5 cm) min.
Fig. 8
Wall bracket location guide
Top view
1"
(26 mm)
Front view
Wall stud
0.438" (11 mm)
(anchor
clearance
points)
3.4"
7"
(17.8 cm)
(87 mm)
1"
(26 mm)
2.44"
(62 mm)
3.50"
89 mm)
4.12"
(10.5 cm)
8
WARNING
Side View
24.5"
(62.3 cm)
25HI
54.5"
(138.5 cm)
50HI
58.5"
(148.6 cm)
14.25"
(36.2 cm)
21.5"
18"
(45.8 cm)
23"
(58.5 cm) min.
Wall stud
Wall stud
25HI400A
13" (33.0 cm)
50HI400A
15" (38.1 cm)
.75"
16.00"
(20 mm)
(40.6 cm)
25HI400A
19" (48.3 cm)
50HI400A
21" (48.3 cm)
6"
Utility
(15.3 cm)
cut-out
Fig. 9
9.1
9.4
17"
(43.2 cm)
23"
1. Using Fig. 8 as a guide, locate wall bracket
mounting position relative to wall studs.
2. Install the supplied wall bracket with six 3/8"
diameter fasteners (Fig. 9.1).
Note: Three holes are available at each fastening
site to allow capture of studs or supports within the
wall.
2. Locate and cut utility hole in wall using Fig. 8
dimensions (9.2).
3. Rough in utilities. Wall mount bracket dimensions
(Fig. 8) can be used as a template.
Water: 1/2" FNPT
Drain: 3/4" FNPT
4. Lift dispenser onto wall bracket positioning unit so
that hook on back of dispenser is captured by wall
bracket support angle (Fig. 9.3).
5. Install two 1/4" X 20 screws through bottom of wall
bracket into bottom of dispenser to secure dispenser
to wall bracket (Fig. 9.4).
6. Install supplied 1/2" MPT X 3/8" push-in adapter
onto 1/2" FNPT water supply.