Cleaning/Descaling And Sanitizing; Weekly; Monthly - Follett Symphony 25CI400A Installation, Operation And Service Manual

Ice and water dispensers
Hide thumbs Also See for Symphony 25CI400A:
Table of Contents

Advertisement

Cleaning/descaling and sanitizing

Periodic cleaning/descaling and sanitizing of Follett's ice and water dispenser and ice machine system is required
to ensure peak performance and delivery of clean, sanitary ice. The recommended cleaning procedures that follow
should be performed at least as frequently as recommended and more often if environmental conditions dictate.
Cleaning of the condenser can usually be performed by facility personnel. Cleaning/descaling and sanitizing of the
ice machine system should be performed by your facility's trained maintenance staff or a Follett authorized service
agent. Regardless of who performs the cleaning, it is the operator's responsibility to see that this cleaning is performed
according to the schedule below. Service problems resulting from lack of preventive maintenance will not be covered
under the Follett warranty.
Recommended cleaning/descaling and sanitizing intervals*
Symphony
Drain Line
Drain Pan/Drip Pan
Exterior
Air Filter
Condenser
Dispenser and Components
Ice Machine
Transport Tube
Ice Storage Area/Bin
*
Ice machine and dispenser must be cleaned and sanitized prior to start-up.

Weekly

§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser.
Dispenser drain pan and drain line
1. Pour 1 gal. (3.8 L) of hot tap water into drain pan to fl ush drains.
Splash panel front, SensorSAFE infrared dispensing
1. Deactivate dispensing by pressing and releasing clean switch located on left side of unit under top front
cover.
2. Clean lens and splash panel front using a soft cloth and mild, non-abrasive, non-chlorine based cleaner.
3. Reactivate dispensing by pressing and releasing clean switch again.

Monthly

§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser.
Condenser (air-cooled ice machine only)
1. Use a vacuum cleaner or stiff brush to carefully clean condenser coils of lint and debris to ensure optimal
performance.
Air Filter
1. Remove screw at top of louvered panel on left side of unit.
2. Slide panel toward back of dispenser and lift.
3. Remove the air fi lter located under the louver.
4. Clean with soap and water.
5. Rinse, and replace when completely dry.
10
Frequency
weekly
weekly
as needed
monthly
monthly (air-cooled only)
semi-annually
semi-annually
semi-annually
semi-annually
CAUTION!
CAUTION!
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A

Hide quick links: