Refrigeration data

Ice production

Air-cooled icemaker capacity/24 hrs.
Ambient Air Temperature F/C
60
70
80
90
100
F
C
16
21
27
32
38
425
395
360
330
295
50
10
193
180
164
150
134
60
410
380
345
315
285
186
173
157
143
130
16
70
395
365
330
300
270
180
166
150
137
123
21
80
380
350
318
285
255
173
159
145
130
116
27
90
365
335
305
273
243
32
166
152
139
124
111

Ice capacity test

Ice machine production capacity can only be determined
by weighing ice produced in a specifi c time period.
1. Remove top panel and hopper lid of unit.
2. Weigh and record weight of container used to
catch ice.
3. Run ice machine for at least 15 minutes.
4. Catch ice for 15 or 20 minutes.
5. Weigh harvested ice and record total weight.
6. Subtract weight of container from total weight.
7. Convert fractions of pounds to decimal equivalents
(Ex. 6 lbs 8 oz = 6.5 lbs).
8. Calculate production using following formula:
1440 min. × wt. of ice produced
Total test time in minutes
9. Calculated amount per 24 hours should be checked
against rated capacity for same ambient and water
temperatures in Ice Production Table (above).

Compressor current draw

Air-Cooled Ambient Air Temperature
Fahrenheit
60 F
70 F
Celsius
15.6 C
21.1 C
Locked Rotor Amps
58.8

Gearmotor data

Gearmotor current
2.25A (nominal)
Locked Rotor Amps
14
30
Water-cooled icemaker capacity/24 hrs.
Ambient Air Temperature F/C
F
60
70
80
90
16
21
27
32
C
lbs.
50
430
425
418
390
kg.
10
195
193
190
177
lbs.
415
406
392
368
60
kg.
16
188
184
178
167
lbs.
401
386
365
345
70
kg.
21
182
175
166
156
lbs.
385
365
340
323
80
kg.
27
175
166
154
147
lbs.
368
343
315
300
90
kg.
32
167
156
143
136
production capacity/
=
24 hr. period
80 F
90 F
26.7 C
32.2 C

Refrigeration system

Important: All service on refrigeration system must
be performed in accordance with all federal, state and
local laws that pertain to the use of refrigerants. It is
the responsibility of the technician to ensure that these
100
requirements are met.
38
350
lbs.
159
kg.
334
lbs.
152
kg.
• Recharging of unit at other than factory specifi cations will
318
lbs.
void ice machine warranty
144
kg.
304
lbs.

Ice machine charge specifi cations

138
kg.
290
lbs.
Model
132
kg.
25/50CI400A, 25/50HI400A
25/50CI400W

Refrigerant replacement requirements

1. Non-contaminated refrigerant removed from any
Follett refrigeration system can be recycled and
returned to the same system after completing
repairs. Recycled refrigerant must be stored in a
clean, approved storage container. If additional
refrigerant is required, virgin or reclaimed
refrigerant that meets ARI standard 700-88 must be
used.
2. In the event of system contamination (for example,
a compressor burn out, refrigerant leak, presence
of non-condensibles or moisture), the system must
be repaired, evacuated and recharged using virgin
or reclaimed refrigerant that meets ARI standard
700-88.
3. Follett Corporation does not approve of recovered
refrigerants. Improper refrigeration servicing
procedures will void the factory warranty.

Evacuation

Evacuate the system to a level of 500 microns. When
100 F
the 500 micron level is reached, close valves and shut
37.8 C
down the vacuum pump. Allow the system to sit for
approximately 20 minutes. During this period the system
pressure should not rise. If the system pressure rises
and stabilizes there is moisture in the system and further
evacuation is needed. If the pressure continues to rise
check the system for leaks.

Ambients

Air Temperature
Fahrenheit
Celsius
Water Temperature
Fahrenheit
Celsius
1 - Ambient air temperature is measured at the air-cooled condenser coil inlet.
2 - Ambient water temperature is measured in the ice machine fl oat reservoir.
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
CAUTION
Charge
20 oz
9 oz
1
Minimum
50 F
10 C
2
Minimum
40 F
4 C
Refrigerant
Type
R404A
R404A
Maximum
100 F
38 C
Maximum
90 F
32 C