Pressurized water sanitizing kit
Hide thumbs Also See for Symphony Plus:

Advertisement

Quick Links

For use with systems with no filter
ATTENTION!
These instructions are for Symphony Plus dispensers only.
Instructions for sanitizing Symphony Series dispensers are
located on the reverse side of this document.
Description
Periodic cleaning/descaling and sanitizing of Follett's ice and water dispenser and ice machine system is required
to ensure peak performance and delivery of clean, sanitary ice. Immediately perform Cleaning/Sanitizing procedure
(according to instructions shipped with dispenser) when this Pressurized Water Sanitizing procedure is completed.
If you experience any problems during the installation process, please call Follett Technical Service toll-free at
(877) 612-5086 or +1 (610) 252-7301 for assistance.
Materials Required
§ (1) 1.5 Gallon (or larger) plastic bucket
§ Sanitary gloves
§ Safety glasses
§ 1.6 fl oz of Nu-Calgon IMS-II Sanitizer (P/N 00979674 - 16 fl. oz bottle)
Materials Supplied
(1) Pre-filter bowl
(1) Filter head and bracket
(1) Dip tube
(1) 3/8" ID john guest tubing, 12' (3.6 m)
(2) 1/2" NPT x 3/8" john guest fitting
(1) 3/8" to 3/8" compression fitting
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
Symphony Plus™ Pressurized Water
Sanitizing Kit
P/N 01089580

Installation Instructions

Order parts online:
www.follettice.com
01089820R01

Advertisement

loading

Summary of Contents for Follett Symphony Plus

  • Page 1: Installation Instructions

    Description Periodic cleaning/descaling and sanitizing of Follett’s ice and water dispenser and ice machine system is required to ensure peak performance and delivery of clean, sanitary ice. Immediately perform Cleaning/Sanitizing procedure (according to instructions shipped with dispenser) when this Pressurized Water Sanitizing procedure is completed.
  • Page 2 1. Unplug dispenser. Fig. 1 2. Turn OFF water supply. 3. Depress red pressure release button to relieve pressure. 4. Remove pre-filter bowl. 5. Install dip tube (Fig. 2). Fig. 2 Symphony Plus Pressurized Water Sanitizing Kit - No Filter...
  • Page 3 1.6 oz (47 ml) Nu-Calgon IMS-II Sanitizer (P/N 00979674). Fill pre-filter bowl to just below the o-ring with sanitizing solution (Fig. 3). 8. Re-install pre-filter bowl (Fig. 4). Fig. 4 Symphony Plus Pressurized Water Sanitizing Kit - No Filter...
  • Page 4 18. Ice machine will resume ice making mode (wait for MAKING ICE light to turn on) and sanitizer will fill the ice machine water lines and also the water reservoir. Symphony Plus Pressurized Water Sanitizing Kit - No Filter...
  • Page 5 (wait for MAKING ICE light to turn on) and flush water reservoir lines. 30. Turn OFF the BIN SIGNAL switch. 31. Immediately perform Cleaning/Sanitizing procedure according to instructions shipped with dispenser. 30 sec Symphony Plus Pressurized Water Sanitizing Kit - No Filter...
  • Page 6 Follett is a registered trademark of Follett Corporation, registered in US. 801 Church Lane • Easton, PA 18040, USA 01089820R01 Toll free (877) 612-5086 • +1 (610) 252-7301 © Follett Corporation 6/15 www.follettice.com...