Installing Wall Mount Dispensers - Follett 25HI425A Installation, Operation And Service Manual

Ice and water dispensers
Table of Contents

Advertisement

Installing wall mount dispensers

WARNING!
§ Wall mount dispensers are intended to be mounted
above a sink, eliminating the need for a drain pan.
§ Before beginning installation verify that the sink size
and location meet the requirements shown in Fig. 6.
§ If requirements are not met, a drain pan must be
used to prevent ice and water from falling on counter
or floor.
§ FAILURE TO TAKE THESE PRECAUTIONS
COULD RESULT IN SLIPS AND FALLS ON WET
FLOORS
8
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
Fig. 6 – Minimum sink requirements (without drain
pan), front view
Front View
Sink centered
below chutes
21.50"
(54.7 cm)
14.25"
(36.2 cm) min.
Fig. 7 – Minimum sink requirements (without drain
pan), side view
SIDE VIEW
24.36" (61.9 cm)
17.01"
(43.2 cm)
18.92"
(48.1 cm)
30.00" (76.2 cm)
MIN DISTANCE TO SINK FRONT
Front View
Sink centered
below dispenser
21.50"
(54.7 cm)
23.00"
(58.5 cm) min.
25HI425
35.88" (91.1 cm)
50HI425
39.88" (101.3 cm)
18.00" (45.7 cm)
SUGGESTED POWER
CORD ROUTING