4-1. TROUBLESHOOTING GUIDE

PROBLEM
Product not
holding
temperature
Doors are
fogging
Water will
not fill
Lights will
not turn on
Not all lights
on
Water will not
reach desired
temperature
More detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com,
4-1

SECTION 4. TROUBLESHOOTING

CAUSE
Doors are not kept closed
Product held too long
Water temperature too low
Radiant heat too low
Light bulbs out
Doors left open too much
allowing doors to cool and
cause condensation
Radiant heat not high enough
Water temperature too high
Water supply has been shut-
off or disconnected
Defective fuse
Faulty light bulbs
Bun pans are not over water
or 800-417-8405 or 937-456-8405.
Model CW-216/CW-114
CORRECTION
Keep doors closed when
possible
Only hold product for
recommended times
Turn to higher setting
Turn to higher setting
Replace as required, per
Light Bulbs and Glass Panels
Section
Keep doors closed when
possible
Turn to higher setting
See recommended settings
and temperatures
Check the water supply
Replace 15 amp fuse
Replace with recommended
bulb, per Light Bulbs and Glass
Panels Section
Place perforated bun pans
over water
203