TROUBLESHOOTING GUIDE

PROBLEM
Product not holding
Doors are fogging
Lights will not turn
on
Not all lights on
More detailed troubleshooting information is available in the Technical Manual, available at

SECTION 4. TROUBLESHOOTING

CAUSE
Doors are not kept closed
Product held too long
Temperature too low
Radiant heat too low
Light bulbs out
Doors left open too much allowing
doors to cool and cause condensation
Radiant heat not high enough
Temperature too high
Defective fuse
Faulty light bulbs
www.hennypenny.com, or 800-417-8405 or 937-456-8405.
Keep doors closed when holding possible
Only hold product for recommended times
Turn to higher setting
Turn to higher setting
Replace as required, per light Bulbs and
Glass Panels section
Keep doors closed when possible
Turn to higher setting
See recommended settings and temperature
Replace 15 amp fuse
Replace with recommended bulb, per Light
Bulbs and Glass Panels section