These are the original version controlled Henny Penny instructions for Multipurpose Holding Cabinet (MPC) Model MPC - 554, 1L, and 22. This manual is available on the Henny Penny Public website (www.hennypenny.com). Read these instructions completely prior to installation and operation of this appliance to ensure compliance to all required installation, operation and safety standards.
Page 5
During this time, any frypot that fails due to manufacturing or workmanship issues will be replaced at no charge for parts, labor, or freight. Henny Penny will either install a new frypot at no cost or provide a new or reconditioned replacement fryer at no cost.
If a problem occurs during the first operation of a new cabinet. 1-2. SAFETY The Henny Penny unit has many safety features incorporated. However, the only way to ensure safe operation is to fully understand the proper installation, operation, and maintenance procedures.
Model MPC-1L, MPC-22, MPC-554 These two test instruments will help to check the electrical 1-3. TEST INSTRUMENTS components: 1. A voltmeter 2. An ohmmeter. When the manual refers to the circuit being closed, the ohmme- ter should read zero unless otherwise noted. When the manual refers to the circuit being open, the ohmmeter will read infinite resistance.
Page 8
Model MPC-1L, MPC-22, MPC-554 1-4. TROUBLESHOOTING (Continued) PROBLEM CAUSE CORRECTION • Verify set-point reading; if zone (see Zone Unit will not heat • Control board not calling Positions at left) tempeature is below for heat setpoint and not calling for heat...
Model MPC-1L, MPC-22, MPC-554 1-4. TROUBLESHOOTING (Continued) PROBLEM CAUSE CORRECTION Product not holding • Heat settings too low • Have heat zones set to factory default temperature temperatures • Low or improper voltage • Using meter, compare receptacle voltage to data plate voltage •...
Model MPC-1L, MPC-22, MPC-554 SECTION 2. SPECIAL PROGRAMMING MODE 2-1. INTRODUCTION This mode records historic information on the holding cabinet and operator performance, which could help in troubleshooting a problem. 2-2. ACCESSING SPECIAL PROGRAMMING MODE To access Special Programming Mode, perform the following procedure: 1.
Model MPC-1L, MPC-22, MPC-554 2-4. PROGRAMMING Always press the P button to advance to the next step. DESCRIPTIONS Press and hold the P button at any time to exit Special Programming mode. Description Action 1. °F/°C Press the UP/DOWN button to toggle the mode.
Model MPC-1L, MPC-22, MPC-554 SECTION 3. MAINTENANCE This section provides procedures for the checkout and replace- 3-1. INTRODUCTION ment of the various parts used in the cabinet. Before replacing any parts, refer to the Troubleshooting section. It will aid you in determining the cause of the malfunction.
Model MPC-1L, MPC-22, MPC-554 Replacement: 3-3. CONTROL BOARD 2. Disconnect the two large, white connectors and remove (Continued) component panel from unit. 3. Remove the connectors to the control board. Figure 2. 4. Using a 1/4” socket or wrench, remove the 4 nuts securing...
Model MPC-1L, MPC-22, MPC-554 Checkout (Continued) 3-4. TRANSFORMER If transformer has 120V at the primary terminals, but more than REPLACEMENT 14 volts, or less than 10 volts at secondary terminals, replace (Continued) transformer. Replacement: 2. Disconnect the two large, white connectors and remove component panel from unit.
Page 15
Model MPC-1L, MPC-22, MPC-554 3-5. RELAY REPLACEMENT 4. With the component energized, 0 volts should show on the output side of the relay, and 5 vdc on the input side. Also, (Continued) check for correct polarity into the relay-reference wiring diagram.
Model MPC-1L, MPC-22, MPC-554 3-6. POWER SWITCH & LED REPLACEMENT To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. Power Switch Checkout: 1. Locate the small access panel on the side of the unit and using a Phillip’s-head screwdriver, loosen the screw securing the...
Model MPC-1L, MPC-22, MPC-554 3-7. MPC-554 LINER/HEATER ASSY. REPLACEMENT To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. Checkout: 1. Slide the component panel out as described in the first step in Section 2-3.
Page 18
Model MPC-1L, MPC-22, MPC-554 3-7. MPC-554 LINER/HEATER ASSY. REPLACEMENT (Continued) 7. Using a 5/16” socket or wrench, remove the 5 nuts on the rear of the front panel. Figure 4. Figure 4 8. Using a drill-out the pop-rivets securing the 1/8”...
1, and unit is now ready for use. 3-8. MPC-22 & MPC-1L For possible heater or temperature sensor failure on MPC-22 LINER/HEATER ASSY. and MPC-1L’s, please call Technical Support at 1-800-417- REPLACEMENT 8405/ 1-937-456-8405, or technicalservice@hennypenny.com. Sept. 2011...
Model MPC-1L, MPC-22, MPC-554 SECTION 3. PARTS INFORMATION 3-1. INTRODUCTION This section lists the replaceable parts of the Henny Penny MPC units. 3-2. GENUINE PARTS Use only genuine Henny Penny parts in your cabinet. Using a part of lesser quality or substitute design may result in damage to the unit, or personal injury.
Page 23
Model MPC-1L, MPC-22, MPC-554 MPC-554/MPC-1L/MPC-22 Item No. Part No. Description Quantity B 1 30978 Transformer Assembly - 120VP-12VS-20VP A 2 40645 Relay - 25A - Solid State As Required B 3 73602 Control - MPC Recommended Parts: A=Truck Stock/B=Dist. Stock...
Page 24
Decal - Power Switch - MPC-22 ME50-021 Terminal Block - MPC-554 (not shown) Note: For possible heater or temperature sensor failure on MPC-22 and MPC-1L’s, please call Technical Support at 1-800-417-8405/ 1-937-456-8405, or technicalservice@hennypenny.com. Recommended Parts: A=Truck Stock/B=Dist. Stock May 2013...
Page 25
Assy- MPC22 Liner Top 100V * Applies on units manufactured prior to June 2017. Note: For possible heater or temperature sensor failure on MPC-22 and MPC-1L’s, please call Technical Support at 1-800-417-8405/ 1-937-456-8405, or technicalservice@hennypenny.com. Recommended Parts: A=Truck Stock/B=Dist. Stock Oct.
Page 26
Henny Penny Corporation P.O. Box 60 Eaton, OH 45320 1-937-456-8400 1-937-456-8402 Fax Toll free in USA 1-800-417-8417 1-800-417-8434 Fax *FM06-038-B* www.hennypenny.com Revised October 2018...