Assign Function Settings - Roland V-Bass Owner's Manual

Table of Contents

Advertisement

Chapter 2. Creating sounds

Assign function settings

Set this when you want to control parameters using an
external pedal or MIDI device connected to the V-Bass. You
can also make settings to control several parameters
simultaneously. For each patch number, you can specify
eight parameters (Assign numbers 1–8) that will be
controlled by a controller you specify.
* As an example here, we will describe how to make settings for
Assign 1. You can use the same procedure for making Assign
settings 2–8.
1. Press [PEDAL ASSIGN].
fig.2-10
fig.2-11
2. Press [PAGE
] to move to page 2.
fig.2-17
3. Press [F2] (ON/OFF) to switch the Assign function on/
off.
fig.2-19
4. Turn the VALUE dial to select "CUSTOM" or PRESET.
5. If you wish to edit further, press [F5] (EDIT).
fig.2-20
6. Press [F1] (TARGET), and use the VALUE dial to select
the target.
* Press [F2] (NEXT GROUP) to cycle through these choices:
COSM BASS, COSM AMP, the various effects, and FX
BYPASS on/off.
26
7. Press [F4] (MIN), and use the VALUE dial to specify the
minimum value.
8. Press [F5] (MAX), and use the VALUE dial to specify
the maximum value.
9. Press [F3] (SOURCE), and use the VALUE dial to select
the source.
10. Press [F6] (MODE), and use the VALUE dial to select
the mode.
11. Press [PAGE
] to move to page 2.
fig.2-21
12. Press [F1], and use the VALUE dial to set ACTIVE
RANGE LO.
* You can press [F4] (LO SET) to specify the current value of
the source.
13. Press [F2], and use the VALUE dial to set ACTIVE
RANGE HIGH.
* You can press [F5] (HI SET) to specify the current value of the
source.
14. If you want to save the edited settings, perform the
Write procedure (p. 30).
* If you do not want to save, press [EXIT] to return to the Play screen.
Active Range:
about the variable range of a controller
This setting specifies the operating range in which the value
will change when the source you are using is a continuously
variable controller, such as an expression pedal. Even if you
move the controller outside of this range, the value will not
change; it will stay at the "minimum value" or "maximum
value."
(Example)
When ACTIVE RANGE LO:40 and ACTIVE RANGE HI:80
fig.2-22a
Max.Value
Target
Max
Min.Value
Target
Min
0
40
80
Act.Range
Act.Range
Lo
Hi
* If you are using an on/off type controller such as a foot switch
as the source, please leave this at the "LO:0" and "HI:127"
settings. With other settings, the value may fail to change.
On
ON
Off
OFF
0
40
60
80
127
Act.Range
Median
Act.Range
Lo
Value
Hi
127

Advertisement

Table of Contents
loading

Table of Contents