Troubleshooting
Troubleshooting
Procedures
Unless it is necessary to turn on the machine to do the procedure, always unplug the power cord
from the wall outlet, and wait 5 minutes before performing repairs.
Some components of the equipment can be heavy or awkward. Enlist the service of a second person when you
do maintenance steps involving these components.
Do not tryto
do heavy or awkward steps on your own.
Unit will not power up/turn on/
start
Outlet
Power cord not plugged in
Make sure outlet is functioning
correctly. Verify this
by plugging another object (ex: lamp) into the outlet.
If outlet is connected to a light switch, check to make
sure it is on. If outlet is not functioning find a working
outlet.
Make sure the power cord is firmly secured to AC inlet
on the unit and firmly inserted into a non-GFI (and non-
AFI) wall socket.
Power switch turned off
Make sure the power switch at the rear of the unit is in
the "ON" position.
Safety key not plugged in
Plug Safety Key into console. (See Emergency Stop
Procedure within the Important Safety Precautions
section.)
Remove rear plastic covers and contact customer
service for assistance.
LEB Biagnostic needed
Display setto wrong unit of
measure (English/Metric)
Out of calibration
Transmitter not making good
contact with skin
Speed displayed is not accurate
Change display units (See Owner's Manual).
Re-calibrate machine. (See Calibration procedure in
this manual.)
Heart rate not displayed while
Make sure heart rate monitor is under clothing, against
using chest strap (TO5000 only)
the skin, and as high under the pectoral muscles as is
comfortable.
Use saline solution (saliva or contact lens
solution) to wetthe
electrode areas on the sensor unit.
Electromagnetic
interference
Chest strap transmitter
HR receiver
Turn off any television, AM radio, microwave, or
computer within 6 feet (2 meters) of the TreadClimber ®
fitness machine. Try positioning the machine in another
area.
Test chest strap with another HR monitoring device
such as HR watch or a machine at a gym. If
transmitter has good skin contact and still is not
found to be emitting HR signal, replace chest strap
transmitter.
If chest strap is known to work with other devices and
no sources of interference
are present, or console has
been tested with a Pulse Simulator and is not receiving
the signal, replace the HR receiver.
I Walking belt misalignment
Rear belt guides
Belts should ride on top of triangular black belt guides
at rear of treadles.
Tracking adjustment
Belts are not required to be perfectly centered and
are typically farther out in the rear than they are in the
front. This may vary depending on user's stride. If belt
is tracking to one side far enough to cause rubbing of
belt, follow Belt Alignment procedure in this manual.
32