Peco Performance Pro T12000 Series Installation Manual page 3

Thermostats
Hide thumbs Also See for Performance Pro T12000 Series:
Table of Contents

Advertisement

System Type 11: 3H/2C Heat Pump
TERM
Function
C
Common
B/O
Reversing Valve
AUX
Auxiliary Heat
G
Fan
A
Economizer/Damper
E
Emergency Heat
Y1
Compressor 1
Y2
Compressor 2
RH
Power for Heating
RC
Power for Cooling
System Type 13: 3H/2C Conventional
TERM
Function
C
Common
W1
Heat 1
W2
Heat 2
G
Fan
A
Economizer/Damper
E
Heat 3
Y1
Cool 1
Y2
Cool 2
RH
Power for Heating
RC
Power for Cooling
Part II: attach wIres to thermostat wallPlate (cont.)
2. Using a small fl athead screwdriver, loosen the screws on the terminal blocks that
correspond to the system type (see Table 1).
3. Strip the insulation of each wire at a proper length (about 1/4" or 64 cm).
4. On the wallplate, insert wires into the terminal blocks that correspond to the system
type, then re-tighten each screw for each terminal (see Fig. 4, enlarged area).
note: Do not over-tighten screws or use excessive force.
5. Assure that no uninsulated wires are exposed: Cap off and place a wire-nut on any
unused wires. Assure that the attached wires fi t into the cavity on the back side of the
thermostat.
Figure 4. Insert wires
into appropriate
terminal blocks.
Part III: connect Power to the thermostat wallPlate
1. Choose from the following options to power the thermostat.
Power options
The T12000 Series will operate on 24 VAC power and/or two AA batteries (both are
recommended). Choose from three methods to connect power to the thermostat.
• Batteries only (AA alkaline)
• 24 VAC direct connection only
• 24 VAC with AA battery backup (highly recommended)
wiring 24 vac common
• single-transformer system: Connect the common side of the transformer to
the "C" screw terminal of the thermostat wallplate. Assure that the metal jumper
connects "RC" and "RH." Connect power side to the RC/RH and assure that the
jumper remains in place.
• two-transformer system: The T12000 Series is shipped with a jumper connecting
terminals RH and RC. If the heating and cooling equipment do not use separate
transformers, leave this jumper in place. If separate transformers are required,
remove this jumper. With the jumper removed, connect RC to the power side of the
cooling transformer. Connect RH to the power side of the heating transformer; then
connect both the heating and cooling commons together to terminal C (Common).
© COPYRIGHT 2010 PECO, INC. ALL RIGHTS RESERVED.
System Type 12: 3H/1C Conventional
TERM
Function
C
Common
W1
Heat 1
W2
Heat 2
G
Fan
A
Economizer/Damper
E
Heat 3
Y1
Cool 1
Y2
RH
Power for Heating
RC
Power for Cooling
caUtIon: Do not connect
!
unused wires together
Enlarged area
shows wire
insertion point
above terminal
block.
Part Iv: Install BatterIes & remove taB
1. Insert two AA batteries (included) into the back compartment of the thermostat, where
indicated (see Fig. 5).
2. Remove the plastic insulator tab from the back side of the thermostat (see Fig. 6).
IMPORTANT: The insulator tab must be removed before setting the real-time clock.
Insulator tab
Part v: set the clock, month, anD DaY
When power is fi rst applied to the thermostat, it will activate the clock display. It is
recommended that time and day are entered before performing advanced confi guration.
On the touchscreen area, follow the procedure below to set the clock, month, and day.
note: Flashing option is selected. Press
1. From the Home Display, Press
Clock
1. Press ▲/ ▼ to select 12 or 24 HR mode, then press
2. Press ▲/ ▼to select clock hour, then press Clock.
3. Press ▲/▼to select clock minutes, then press Clock.
4. Press ▲/ ▼ to select clock year, then press Clock.
5. Press ▲/ ▼ to select current month, then press Clock. note:
6. Press ▲/ ▼to select current numerical date. note:
7. Press
to fi nish
mode.
Done
Clock
Part vI: verIFY sYstem settInG Is tUrneD oFF
note: the fl ashing option is the default selection.
1. Press any part of the touchscreen area to enter the Home Display.
2. Press
to enter system mode.
System
3. Press
repeatedly until "Off" fl ashes, then press Done.
System
4. Press
key to enter fan mode.
Fan
5. Press
repeatedly until "Auto" fl ashes, then press Done.
Fan
Part vII: PerForm aDvanceD conFIGUratIon
Perform advanced confi guration before attaching the thermostat to the wallplate.
Advanced confi guration is done by simultaneously pressing the lower left and lower right
touchscreen area for about fi ve seconds (See Fig. 8), which gives user access to Service
Menus. UseTable 2 of this Installation Guide to set each desired Service Menu item.
Advanced confi guration allows the user to confi gure the thermostat to match the system
type and to customize several thermostat settings.
3
Insert two AA batteries
in back of thermostat.
Remove the insulator
tab from thermostat
before operation.
to advances to next menu option.
Clock
key.
Clock.
appears.
Mo
appears.
Days
Clock must be set
before performing
confi guration.
Access Service Menus
by pressing the lower
right and lower left
touchscreen areas
simultaneously.
P/N 70480 3220-2269 REV 00
Figure 5.
Figure 6.
Figure 7.
advanced
Figure 8.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Performance pro t12500

Table of Contents