C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance "M" from the surface of the glass
door.
K
Figure 9.1
Hearth Pad Requirements
Sides
K
Back
L*
Front
M
*L Exception for Horizontal Installations:
If optional Cast Base is installed use
USA INSTALLATIONS:
a non-combustible floor protector extending under unit and to
the sides, front and back of unit as shown in Floor Protection
Diagram. Measure front distance (M) from the surface of the
glass door.
If Cast Base is not installed, the non-combustible floor protec-
tor must be 1/4 inch (6mm) minimum thickness ("k" value =
0.84).
A non-combustible floor protection extending beneath the
flue pipe is recommended with horizontal venting or under
the top vent adapter with vertical installation. Figure 9.2.
CANADA INSTALLATIONS: A non-combustible floor pro-
tection extending beneath the flue pipe is required with
horizontal venting or under the top vent adapter with vertical
installation.
September 1, 2008
L*
K
M
Inches
Millimeters
2
51
2
51
6
152
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
Figure 9.2
7001-142D