C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance "M" from the surface of the glass
door.
K
Figure 10.1
USA Installations
Hearth Pad Requirements
K
Sides
L*
Back
M
Front
CANADA Installations
Hearth Pad Requirements
K
Sides
L*
Back
M
Front
*L Exception for Horizontal Installations:
See Figure 10 2
USA INSTALLATIONS: A non-combustible floor protection is
recommended extending beneath the flue pipe when installed
with horizontal venting or under the Top Vent Adapter with
vertical installation.
CANADA INSTALLATIONS: A non-combustible floor pro-
tection extending beneath the flue pipe is required with hori-
zontal venting or under the Top Vent Adapter with vertical
installation.
Page 10
L*
K
M
Inches
Millimeters
2
51
2
51
6
152
Inches
Millimeters
8
203
2
51
18
457
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
Figure 10.2
7021-130E
Castile-B FS Pellet Stove
November 13, 2013