Specifications

Input Rates

Natural Gas
17,000 BTU/hr. maximum input
9,900 BTU/hr. minimum input
Propane
16,000 BTU/hr. maximum input
8,700 BTU/hr. minimum input
Inlet Pressure:
MIN
Natural Gas: 5.0 WC (1.24 kPa)
Propane:
12.0 WC (2.98 kPa)
Manifold Pressure:
MIN
Natural Gas: 1.2 WC (0.29 kPa)
Propane:
2.9 WC (0.72 kPa)
Piezo Ignitor / Standing Pilot
Weight: 150 lbs.
The Jøtul GF 100 DV II Nordic QT is a Direct Vent gas
heater designed as a sealed combustion, air circulat-
ing gas appliance for residential applications. This
appliance is approved for installation using
6 5/8" X 4" direct vent pipe and components from the
following manufacturers:
Simpson Dura-Vent GS
Security Vent, Ltd.
Amerivent Inc.
Selkirk Metalbestos
Metal-Fab, Inc.
ICC, Inc. - ExcelDirect Vent
The Jøtul GF 100 DV II Nordic QT gas stove is designed
to burn NATURAL GAS or PROPANE only. It is shipped
from the factory equipped to burn Natural Gas. If use
with Propane is desired, the stove must first be con-
verted for use with that gas. Use the LP Fuel Conver-
sion Kit 155628 included with this stove. See page 14
for instructions.
Jøtul GF 100 DV II Miscellaneous Kit
Contents
• Fuel Conversion Kit - LP ...................................155628
• Rear Air Intake Restrictor Plate, ...Black -22111092
• Side Air Intake Restrictor Plates, (2) ....... 22099192
* Decorative Wall Shield, Black ................. 22092692
4
MAX
7.0 WC (1.74 kPa)
14.6 WC (3.63 kPa)
MAX
3.8 WC (0.94 kPa)
11.0 WC (2.74 kPa)
or Jøtul Iron - 22111085
or Jøtul Iron - 22099185
or Jøtul Iron ......... 22092692
18 1/4"
464 mm
Leg To
Leg
14"
356 mm
Jøtul GF 100 DV II Accessories
• Blower Kit ............................................................155631
• Antique Brick Kit ................................................155815
• Fuel Conversion Kit - NG ................................ 155629
• Wall Thermostat ............................................. 750003
• Remote Control ...............................................129706
• Mobile Home Floor Bracket Kit .....................154342
Universal Leg Leveler Kit ............................... 156096
21"
533 mm
22 1/4"
565 mm
16 3/4 "
425 mm
Flue Collar
Centerline
16 3/4"