Replacing The I/O Riser Card; Replacing The Remote Management Module; Replacing The Sas/Sata Raid Controller Card - Fujitsu PRIMERGY RX600 S6 Service Supplement Manual

Hide thumbs Also See for PRIMERGY RX600 S6:
Table of Contents

Advertisement

Replacement routines
4.3

Replacing the I/O riser card

The I/O riser card is replaced the same way as a non-hot-plug controller. A
description can be found in the Options Guide for this server.
4.4

Replacing the Remote Management Module

The Remote Management Module (Intel® RMM3) is located on the I/O riser
card. The Remote Management Module is delivered with the I/O riser card only
and thus it can only be replaced with the complete I/O riser card.
4.5
Replacing the SAS/SATA RAID controller
card
Ê Open the server as described in
Figure 8: Replacing the SAS/SATA RAID controller card
Ê Disconnect the HDD-activity cable (1) and both SAS cables (2) & (3) from
the SAS/SATA RAID controller card.
Ê Open the slot lock and remove the defective SAS/SATA RAID controller
card.
To install the new SAS/SATA RAID controller card follow the above steps in
reverse.
26
section "Opening the server" on page 21
Service Supplement
RX600 S6

Advertisement

Table of Contents
loading

Table of Contents