Replacement routines
Installing the hot-swap backplane
Figure 15: Installing the hot-swap backplane
Ê Set the hot-swap backplane into position by lowering it over the metal tabs
(see arrows in figure above).
Ê Plug all relevant cables into the hot-swap backplane (see the cabling plan in
the appendix of the Options Guide).
Ê Plug the cable from the power distribution board to the front panel fan board.
Ê Plug the cable from the system board to the front panel fan board.
Ê Reinstall the memory rug (see
Ê Push all HDD/SSD modules and the optical drive back into their bays in the
housing until they engage.
Ê Plug all memory boards and memory dividers back into their slots.
Ê Close the server as described in
This completes the replacement of the hot-swap backplane.