Address
Description
10X32
-
10X33
upsStatusEcomodeIsOn
10X34
upsStatusBatteryIsCharging
10X35
upsStatusBatteryIsDischarging
10X36
upsStatusAlarmIsActive
10X37
upsStatusRectifierIsOn
10X38
upsStatusStopOperation
10X39
upsStatusOnBypass
10X40
upsStatusMainsBypassOK
10X41
upsStatusMainsRectifierOK
10X42
upsStatusDetourIsOn
10X43
upsStatusAcousticAlarmIsOn
10X44
upsStatusServiceCheck
10X45
upsStatusInverterIsOn
10X46
upsStatusNotInParallel
10X47
upsStatusResetLoadOff
10X48
upsStatusLoadOff
10X49
upsStatusBoostMode
10X50
upsStatusBuckMode
10X51
upsStatusIemModeIsOn
10X52
upsStatus5thFilterIsOn
10X53
upsStatus11thFilterIsOn
10X54
upsStatus2ndRectifierBridgeIsOn
10X55
-
10X56
-
10X57
-
10X58
-
10X59
-
10X60
-
10X61
upsGlobalParallelValues
10X62
-
10X63
-
10X64
-
NOTE:
Registers 10X26 – 10X31 hold different contents in 1-ph and 3-ph UPS.
Registers 10X33 – 10X64 are only available on 3-ph UPS.
NOTE:
GT Series 5-10kVA UL UPSs are 2-ph systems.
In this case, the L-L voltage is mapped to Line3 Voltage registers.
Modifications reserved
OPM_CNT_SNM_BAS_CRD_1GB_V014.doc
Notes
Not Used (Reserved)
Ecomode is ON.
Battery is being charged.
The UPS is drawing power from the batteries. Identical to
upsAlarmOnBattery.
UPS has a general fault. Identical to upsAlarmGeneralFault.
Rectified is ON.
The remaining battery run time is less than or equal to
upsConfigLowBattTime or any other condition exist, such
that the output will be disconnected in a short time.
The Bypass is presently engaged on the UPS. Identical to
upsAlarmOnBypass.
All input conditions on the Bypass are OK. Reciprocal to
upsAlarmBypassBad.
All input conditions on the rectifier are OK. Reciprocal to
upsAlarmInputBad.
The manual deviation is on.
The acoustic alarm is on, as a consequence of a new fault.
A general maintenance or a specific UPS component check
is required.
The Inverter is switched on.
The UPS belongs to a parallel system but does not supply
the load (disconnected).
The load is not supplied and special action has to be
performed prior to be able to restart.
The load is not supplied
Boost mode
Buck mode
IEM (Intelligent Energy Management) mode is active
5
order harmonic filter is inserted
th
(SCR-based rectifier only)
11
order harmonic filter is inserted
th
(SCR-based rectifier only)
For units featuring two separate rectifier bridges (typically
large 3-ph UPSs), the 2
nd
Reserved for future enhancements
Reserved for future enhancements
Reserved for future enhancements
Reserved for future enhancements
Reserved for future enhancements
Reserved for future enhancements
The set of registers pertains to the whole parallel system
rather than specific UPS in the system.
Reserved for future enhancements
Reserved for future enhancements
Reserved for future enhancements
rectifier bridge is on.