Diagnostics Error Codes And Suggested Actions; Initialization Error Codes - 3Com 3C389 User Manual

Megahertz 16/4 token ring lan pc card
Table of Contents

Advertisement

5-10
C
HAPTER

Diagnostics Error Codes and Suggested Actions

Initialization Error Codes

Failure during PC Card initialization usually indicates a
hardware error on the PC Card. Reboot your PC using the
diagnostic diskette (TokenDisk diskette #1 is a bootable
diskette), and run the diagnostic program again. If the
3C389 PC Card continues to fail, replace the card and
cable.
One of the following codes will be shown to indicate the
results of the initialization test. The error codes are
displayed in hexadecimal format and represent the
BRING_UP_CODE set by the 3C389 PC Card.
0000
0020
0022
0024
0026
0028
002A
002C
0040
0042
0044
0046
0048
5: T
ROUBLESHOOTING
Initialization success
Diagnostics could not be executed
ROM diagnostics failed
Shared RAM diagnostics failed
Processor instruction test failed
Processor interrupt test failed
Shared RAM interface register diagnostics failed
Protocol-handler diagnostics failed
PC Card's programmable timer for the computer
failed (set by the microcode)
Cannot write to shared RAM (set by microcode)
Reading from shared RAM read-only area
caused an incorrect error indication (interrupt)
Writing into shared RAM read-only area did not
cause an error indication (interrupt)
Initialization timed out

Advertisement