D621 User's Guide
Turn the System On with Points Faulted (Force
Arm)
Force-arming is not permitted in UL applications.
IMPORTANT
1.
To force arm the system All On or Part On with the normal Exit
Delay time and tone, press [ALL ON] or [PART ON]. The faulted
point's LED indicator remains on. The Cmd indicator turns on. Press
[ALL ON] or [PART ON] again. If the Cmd indicator flashes fast,
enter your passcode. The All or Part indicator turns on, indicating
the system is turning All On or Part On. The Exit Delay Time
countdown begins with the exit tone. The faulted point's LED
indicator flashes indicating that this point is force-armed.
2.
To force arm the system All On or Part On with doubled Exit Delay
time and no exit tone, press and hold [ALL ON] or [PART ON] until
the Cmd LED lights (after approximately 1 sec.). The faulted point's
LED indicator remains on. Press [ALL ON] or [PART ON] again. If
the Cmd indicator flashes, enter your passcode. The All or Part
indicator turns on, indicating the system is turning All On or Part
On. The Exit Delay Time countdown is doubled and begins without
the exit tone. The faulted point's LED indicator flashes indicating that
this point is force-armed. Once the panel is armed, the Cmd
indicator turns off.
The system "forces" the faulted points on. As long as they remain
faulted they do not provide protection. If they return to normal
before the system is turned off they provide protection and are
capable of starting alarm events. If a point becomes faulted after the
exit delay begins, the Command Center displays the faulted point. If
the point remains faulted at the end of exit delay, it starts an alarm
event.