Section 5.0
Symptom
I
Smoke in
room
II
Wood burns
poorly or is
slow to start
or no heat
III
Dirty glass
IV
Wood burns
too fast

Troubleshooting

Possible Cause
1.
Down draft
2.
Chimney blocked
3.
Chimney damper shut
4.
Baffle out of position
5.
New paint is curing
1.
Low draw
2.
Wet or decayed wood
3.
Blocked intake air
1.
Insert is being under
fired
1.
Too much draft in
chimney
Corrective Action
1.
Upgrade chimney
2.
Clean chimney
3.
Open or remove
damper
4.
Correctly position
baffle
5.
Refer to instructions
1.
Upgrade chimney
2.
Use proper fuel
3.
Check intake air supply
by removing fan from
insert and opening a
window
1.
Refer to instructions
1.
Install manual damper
in chimney connector
pipe.